AEL- Independently Controlled Swimming Pool Packaged Plate Heat Exchangers

SPECIFICATION : Packaged Plate Heat Exchanger c/w Integral control panel, (316) Stainless Steel Plate Heat Exchange

Primary Circuit: Circulation Pump

Secondary Circuit: Check Valve, Outlet Limit Temperature Sensors

From £1,070.00

To select the Plate heat exchanger most suitable for your system please change the KW output below which will automatically increase or decrease the secondary hot water flow rate.

Clear

AEL (SP) Swimming Pool Packaged Plate Heat Exchangers

Independently Controlled Packaged Plate Heat Exchangers c/w Integral Control Panel , Primary Pump ,Temperature Sensors , Secondary Check Valve & Temperature Sensors Built & Ready To Install. Larger units with different design parameters are available.

  • POOL CAPACITY 75,000 LITERS *

    Secondary Pool Water Flow Rate L/S From Cold0.29
    Secondary Pool Water Flow In Temperature °C10
    Secondary Pool Water Flow Out Temperature °C28.5
    Secondary Pressure Drop KPA8.5
    Primary Heating Flow Rate L/S0.18
    Primary Flow In Temperature oC80
    Primary Water Flow Out Temperature °C50
    Primary Pressure Drop KPA68 (Covered By The Primary Pump Supplied)
    Primary KW Required23
    Pool Water Volume Litres75,000
    Model ReferenceAEL-SP-035510
    Dimensions Height 740mm x Length 340mm x Width 255
    Weight Kg31
    Primary Maximum Working Pressure Bar6
    Primary Pipework Connections1" > 1 1/4"
    Pool Water Secondary Pipework Connections1 1/4" > 1 1/4"
    Manufacturers WarrantyAHRI Units 3 years, non AHRI units 1 year.
  • POOL CAPACITY 100,000 LITERS *

    Secondary Pool Water Flow Rate L/S From Cold0.40
    Secondary Pool Water Flow In Temperature °C10
    Secondary Pool Water Flow Out Temperature °C28.5
    Secondary Pressure Drop KPA9.5
    Primary Heating Flow Rate L/S0.24
    Primary Water Flow In Temperature In °C80
    Primary Water Flow Out Temperature °C50
    Primary Pressure Drop KPA53 (Covered By The Primary Pump Supplied)
    Primary Heat KW Power Required30
    Pool Water Volume Liters100,000
    Model ReferenceAEL-SP-050510
    Primary Maximum Working Pressure Bar6
    Dimensions Height 740mm x Length 340mm x Width 255
    Weight31
    Primary Pipework Connections1" > 1 1/4"
    Secondary Pool Water Pipework Connections1 1/4" > 1 1/4"
    Manufacturers WarrantyAHRI Units 3 years, non AHRI units 1 year.
  • POOL CAPACITY 150,000 LITERS *

    Secondary Pool Water Flow Rate L/S From Cold0.58
    Secondary Pool Water Flow In Temperature °C10
    Secondary Pool Water Flow Out Temperature °C28.5
    Secondary Pressure Drop KPA9.5
    Primary Heating Flow Rate L/S0.36
    Primary Water Flow In Temperature °C80
    Primary Water Flow Out Temperature °C50
    Primary Pressure Drop KPA33 (Covered by the Primary Pump Supplied)
    Primary Heat KW Power Required45
    Pool Water Volume Liters150,000
    Model ReferenceAEL-SP-075510
    Primary Maximum Working Pressure Bar6
    DimensionsHeight 740mm x Length 340mm x Width 255
    Weight Kg32
    Primary Heating Pipework Connections1" > 1 1/4"
    Pool Water Pipework Connections11/4" > 1 1/4"
    Manufacturers WarrantyAHRI Units 3 years, non AHRI units 1 year.
  • POOL CAPACITY UP TO 200,000 LITERS *

    Secondary Pool Water Flow Rate L/S From Cold0.77
    Secondary Pool Water Flow In Temperature °C10
    Secondary Pool Water Flow Out Temperature °C28.5
    Secondary Pressure Drop KPA8
    Primary Heating Flow Rate L/S0.48
    Primary Water Flow In Temperature °C10
    Primary Water Flow Out Temperature °C28.5
    Primary Pressure Drop KPA11 (Covered by the Primary Pump Supplied)
    Primary Heat KW Power Required60
    Pool Water Volume Liters200,000
    Model ReferenceAEL-SP-100510
    DimensionsHeight 740mm x Length 363mm x Width 255mm
    Primary Maximum Working Pressure Bar6
    Weight Kg34
    Primary Heating Pipework Connections1" > 1 1/4"
    Pool Water Pipework Connections1 1/4" > 1 1/4"
    Manufacturers WarrantyAHRI Units 3 years, non AHRI units 1 year.
  • POOL CAPACITY UP TO 300,000 LITERS *

    Secondary Pool Water Flow Rate L/S From Cold1.21
    Secondary Pool Water Flow In Temperature °C10
    Secondary Pool Water Flow Out Temperature °C28.5
    Secondary Pressure Drop KPA14
    Primary Heating Flow Rate L/S0.71
    Primary Water Flow In Temperature °C80
    Primary Water Flow Out Temperature °C50
    Primary Pressure Drop KPA24 (Covered by the Primary Pump Supplied)
    Primary Heat KW Power Required90
    Pool Water Volume Liters 300,000
    Model ReferenceAEL-SP-150510
    DimensionsHeight 740mm x Length 377mm x Width 325mm
    Weight Kg41
    Primary Maximum Working Pressure Bar6
    Primary Heating Pipework Connections1 1/4" > 1 1/2"
    Pool Water Pipework Connections1 1/4" > 11/4"
    Manufacturers WarrantyAHRI Units 3 years, non AHRI units 1 year.
  • POOL CAPACITY UP TO 500,000 LITRES *

    Secondary Pool Water Flow Rate L/S From Cold1.54
    Secondary Pool Water Flow In Temperature °C10
    Secondary Pool Water Flow Out Temperature °C28.5
    Secondary Pressure Drop KPA15
    Primary Heating Flow Rate L/S0.95
    Primary Water Flow In Temperature °C80
    Primary Water Flow Out Temperature °C50
    Primary Pressure Drop KPA22 (Covered by the Primary Pump Supplied)
    Primary Heat KW Power Required120
    Pool Water Volume Liters500,000
    Model ReferenceAEL-SP-200510
    DimensionsHeight 740mm x Length 403mm x Width 325mm
    Primary Maximum Working Pressure Bar6
    Weight Kg41
    Primary Heating Pipework Connections1 1/4" > 11/4"
    Pool Water Pipework Connections1 1/4" > 11/4"
    Manufacturers WarrantyAHRI Units 3 years, non AHRI units 1 year.
  • POOL CAPACITY UP TO 600,000 LITERS *

    Secondary Pool Water Flow Rate L/S From Cold2.31
    Secondary Pool Water Flow In Temperature °C10
    Secondary Pool Water Flow Out Temperature °C28.5
    Secondary Pressure Drop KPA19
    Primary Heating Flow Rate L/S1.43
    Primary Heating Water Flow In Temperature °C80
    Primary Heating Water Flow Out Temperature °C50
    Primary Pressure Drop KPA22 (Covered by the Primary Pump Supplied)
    Primary Heat KW Power Required180
    Pool Water Volume Liters600,000
    Model ReferenceAEL-SP-300510
    DimensionsHeight 740mm x Length 452mm x Width 345mm
    Weight Kg46
    Primary Maximum Working Pressure Bar6
    Primary Pipework Connections1 1/4" > 2"
    Secondary Pool Water Pipework Connections1 1/4" > 11/4"
    Manufacturers WarrantyAHRI Units 3 years, non AHRI units 1 year.