Menu Close

Plate Heat Exchangers

Welcome to AEL
image_pdfPDF Page

Supplying the UK Since 1972

Delivered From Stock Within One Week

Manufactured in The UK & Europe

Technical Support With System Advice

Weight N/A
Dimensions N/A

Alfa Laval Domestic Hot Water (DHW) Brazed Plate Heat Exchangers

Instantaneous Domestic Hot Water ( DHW) Alfa Laval Brazed Plate Heat Exchangers 10 KW to 200 KW (Quick to View Standard Designs).

Contact AEL Technical Department For Higher Water Flow Rates & KW Outputs.

From £125.00

To select the Plate heat exchanger most suitable for your system please change the KW output below which will automatically increase or decrease the secondary hot water flow rate.

Clear

Alfa Laval - High Efficiency Domestic Hot Water (DHW) Brazed Plate Heat Exchangers

Alfa Laval Instantaneous DHW Brazed Plate Heat Exchangers Are The Most Efficient Method of Transferring Heat From a Boiler or Heat Pump Into a Separate DHW Circuit. Alfa Laval Brazed PHEs Are Manufactured to European & British Standards So Can Operate Up To A Pressure Of 30 bar Which Makes Them Suitable For a Vast Range of Applications Such As Hotels , Residential Property, Hospitals, Process Plant & Also Adapted For Cooling Applications

  • ALFA LAVAL DHW BRAZED PHE 10 KW *

    Secondary DHW Flow Rate L/S0.047
    Secondary DHW Flow In Temperature °C10
    Secondary DHW Flow Out Temperature °C60
    Secondary Pressure Drop KPA2
    Primary Heating Water Flow Rate L/S0.79
    Primary Heating Flow In Temperature oC 80
    Primary Heating Flow Out Temperature oC 50
    Primary Pressure Drop KPA4
    Primary Heat Load Required KW10
    Model ReferenceAEL-CBH16-9H
    Dimensions H x L x WHeight 210mm x Length 190mm x Width 74mm
    Weight Kg0.8
    Maximum Working Pressure bar32
    Plate Heat Exchanger Material316 Stainless Steel / Cu
    Primary Pipework Connections3/4" > 3/4"
    Secondary Pipework Connections3/4" x>3/4"
    AHRI ApprovedYes
    Manufacturers WarrantyAHRI Units 2 Years / Non AHRI Units 1 Year
  • ALFA LAVAL DHW BRAZED PHE 20 KW *

    Secondary DHW Flow Rate L/S0.095
    Secondary DHW Flow In Temperature °C10
    Secondary DHW Flow Out Temperature °C60
    Secondary Pressure Drop KPA3
    Primary Water Flow Rate L/S0.16
    Primary Heating Flow In Temperature °C80
    Primary Heating Flow Out Temperature °C50
    Primary Pressure Drop KPA6
    Primary Heat Load Required KW20
    Model ReferenceAEL-CBH16-13H
    Dimensions H x W x LHeight 233mm x Length 190mm x Width 93mm
    Weight Kg1
    Maximum Working Pressure bar32
    Plate Heat Exchanger Material316 Stainless Steel / Cu
    Primary Pipework Connections3/4" > 3/4"
    Secondary Pipework Connections3/4" > 3/4"
    AHRI ApprovedYes
    Manufacturers WarrantyAHRI Units 2 Years / Non AHRI Units 1 Year
  • ALFA LAVAL DHW BRAZED PHE 30 KW *

    Secondary DHW Flow Rate L/S0.143
    Secondary DHW Water Flow In Temperature °C10
    Secondary DHW Water Flow Out Temperature °C60
    Secondary Pressure Drop KPA4
    Primary Heating Water Flow Rate L/S0.239
    Primary Heating Flow In Temperature °C82
    Primary Heating Flow Out Temperature °C50
    Primary Pressure Drop KPA8
    Primary Heat Load Required KW30
    Model ReferenceAEL-CBH16-17H
    Dimensions H x L x WHeight 210mm x Length 63mm x Width 63mm
    Weight Kg1.1
    Maximum Working Pressure bar32
    Plate Heat Exchanger Material316 Stainless Steel / Cu
    Primary Pipework Connections3/4" > 3/4"
    Secondary Pipework Connections3/4" > 3/4"
    AHRI ApprovedYes
    Manufacturers WarrantyAHRI Units 2 Years / Non AHRI Units 1 Year
  • ALFA LAVAL DHW BRAZED PHE 40 KW *

    Secondary DHW Flow Rate L/S0.191
    Secondary DHW Flow In Temperature °C10
    Secondary DHW Flow Out Temperature °C60
    Secondary Pressure Drop KPA6
    Primary Heating Water Flow Rate L/S0.319
    Primary Heating Flow In Temperature °C80
    Primary Heating Flow Out Temperature °C50
    Primary Pressure Drop KPA14
    Primary Heat Load Required KW40
    Model ReferenceAEL-CBH16-17H
    Dimensions H x L x WHeight 210mm x Length 63mm x Width 74mm
    Weight Kg1.1
    Maximum Working Pressure bar32
    Plate Heat Exchanger Material316 Stainless Steel / Cu
    Primary Pipework Connections3/4" > 3/4"
    Secondary Pipework Connections3/4" > 3/4"
    AHRI ApprovedYes
    Manufacturers WarrantyAHRI Units 2 Years / Non AHRI Units 1 Year
  • ALFA LAVAL DHW BRAZED PHE 50 KW *

    Secondary DHW Flow Rate L/S0.239
    Secondary DHW Flow In Temperature °C10
    Secondary DHW Flow Out Temperature °C60
    Secondary Pressure Drop KPA5
    Primary Heating Water Flow Rate L/S0.399
    Primary Heating Flow In Temperature °C80
    Primary Heating Flow Out Temperature °C50
    Primary Pressure Drop KPA11
    Primary Heat Load Required KW50
    Model ReferenceAEL-CBH16-25H
    Dimensions H x L x WHeight 210mm x Length 80mm x Width 74mm
    Weight Kg1.4
    Maximum Working Pressure bar32
    Plate Heat Exchanger Material316 Stainless Steel / Cu
    Primary Pipework Connections3/4" > 3/4"
    Secondary Pipework Connections3/4" > 3/4"
    AHRI ApprovedYes
    Manufacturers WarrantyAHRI Units 2 Years / Non AHRI Units 1 Year
  • ALFA LAVAL DHW BRAZED PHE 60 KW *

    Secondary DHW Flow Rate L/S0.287
    Secondary DHW Flow In Temperature °C10
    Secondary DHW Flow Out Temperature °C60
    Secondary Pressure Drop KPA6
    Primary Heating Water Flow Rate L/S0.479
    Primary Heating Flow In Temperature °C80
    Primary Heating Flow Out Temperature °C50
    Primary Pressure Drop KPAAEL-CBH16-25H
    Primary Heat Load Required KW60
    Model ReferenceAEL-CBH16-25H
    Dimensions H x L x WHeight 210mm x Length 80mm x Width 74mm
    Weight Kg1.4
    Maximum Working Pressure bar32
    Plate Heat Exchanger Material316 Stainless Steel / Cu
    Primary Pipework Connections3/4" > 3/4"
    Secondary Pipework Connections3/4" > 3/4"
    AHRI ApprovedYes
    Manufacturers WarrantyAHRI Units 2 Years / Non AHRI Units 1 Year
  • ALFA LAVAL DHW BRAZED PHE 70 KW *

    Secondary DHW Flow Rate L/S0.335
    Secondary DHW Flow In Temperature °C10
    Secondary DHW Flow Out Temperature °C60
    Secondary Pressure Drop KPA27
    Primary Heating Water Flow Rate L/S0.559
    Primary Heating Flow In Temperature °C80
    Primary Heating Flow Out Temperature °C50
    Primary Pressure Drop KPA29
    Primary Heat Load Required KW70
    Model ReferenceAEL-CBH18-23A
    Dimensions H x L x WHeight 316mm x Length 76mm x Width 74mm
    Weight Kg2
    Maximum Working Pressure bar32
    Plate Heat Exchanger Material316 Stainless Steel / Cu
    Primary Pipework Connections3/4" > 3/4"
    Secondary Pipework Connections3/4" > 3/4"
    AHRI ApprovedYes
    Manufacturers WarrantyAHRI Units 2 Years / Non AHRI Units 1 Year
  • ALFA LAVAL DHW BRAZED PHE 80 KW *

    Secondary DHW Flow Rate L/S0.383
    Secondary DHW Flow In Temperature °C10
    Secondary DHW Flow Out Temperature °C60
    Secondary Pressure Drop KPA23
    Primary Heating Flow Rate L/S0.638
    Primary Water Flow In Temperature °C82
    Primary Water Flow Out Temperature °C50
    Primary Pressure Drop KPA26
    Primary Heat Load Required KW 80
    Model ReferenceAEL-CBH18-29A
    Dimensions H x L x WHeight 316mm x Length 89mm x Width 74mm
    Weight Kg2.4
    Maximum Working Pressure bar32
    Plate Heat Exchanger Material316 Stainless Steel / Cu
    Primary Pipework Connections3/4" > 3/4"
    Secondary Pipework Connections3/4" > 3/4"
    AHRI ApprovedYes
    Manufacturers WarrantyAHRI Units 2 Years / Non AHRI Units 1 Year
  • ALFA LAVAL DHW BRAZED PHE 90 KW *

    Secondary DHW Flow Rate L/S0.430
    Secondary DHW Flow In Temperature °C10
    Secondary DHW Flow Out Temperature °C60
    Secondary Pressure Drop KPA11
    Primary Heating Flow Rate L/S0.718
    Primary Heating Flow In Temperature °C80
    Primary Heating Flow Out Temperature °C50
    Primary Pressure Drop KPA26
    Primary Heat Load Required KW90
    Model ReferenceAEL-CBH18-39H
    Dimensions H x L x WHeight 316mm x Length 110mm x Width 74mm
    Weight Kg3.1
    Maximum Working Pressure bar32
    Plate Heat Exchanger Material316 Stainless Steel / Cu
    Primary Pipework Connections3/4" > 3/4"
    Secondary Pipework Connections3/4" > 3/4"
    AHRI ApprovedYes
    Manufacturers WarrantyAHRI Units 2 Years / Non AHRI Units 1 Year