Menu Close

Plate Heat Exchangers

Welcome to AEL
image_pdfPDF Page

Supplying the UK Since 1972

Delivered From Stock Within One Week

Manufactured in The UK & Europe

Technical Support With System Advice

Weight N/A
Dimensions N/A

Manuals

 

pdf icon

Instantaneous DHW System Only Using a PHE Download PDF >

 

pdf icon

Instantaneous DHW System Using a PHE & Cylinder Download PDF >

Technical

 

pdf icon

Technical Dat For TSC1420 Heat Exchangers Download PDF >

 

pdf icon

Technical Dat For TSC510 Heat Exchangers Download PDF >

Guides

 

pdf icon

Guide to Water Flow Rates & Pressure When Sizing Plate Heat Exchanger Download PDF >

 

Calculator

 

pdf icon

DHW Mixing Value Calculator – Reducing DHW from 60 oC to 40 oC Download PDF >

 

Domestic Hot Water (DHW) Alfa Laval Instantaneous Plate & Gasket Heat Exchangers (250KW > 1000KW)

Instantaneous Domestic Hot Water (DHW) Alfa Laval Plate & Gasket Plate Heat Exchangers 30 KW to 1000KW (Quick to View Standard Designs).

Contact AEL Technical Department For Higher Water Flow Rates & KW Outputs.

From £1,146.00

To select the Plate heat exchanger most suitable for your system please change the KW output below which will automatically increase or decrease the secondary hot water flow rate.

Clear

Alfa Laval Domestic Hot Water (DHW) Plate & Gasket Heat Exchangers 250kw > 1000 KW (Standard Designs).

Alfa Laval Instantaneous Domestic Hot Water (DHW) Plate & Gasket Heat Exchangers Are The Most Energy Efficient Method of Generating High Volumes of DHW to Taps & Showers In Many Applications Such as Schools , Hotels , Hospitals , Residential Property , Process Plant Wash Down etc. Higher Outputs And Designs Are Available.

  • Heat Load 250 KW *

    Secondary DHW Flow L/S1.20
    Secondary DHW Flow In Temperature oC 10
    Secondary DHW Flow Out Temperature °C60
    Secondary Pressure Drop KPA26
    Primary Flow L/S2.0
    Primary Flow In Temperature oC80
    Primary Flow Out Temperature °C50
    Primary Pressure Drop KPA52
    Model ReferenceAEL-T5-MFG-16
    Dimensions mmHeight 700mm x Length 170mm x Width 260mm
    Weight Kg80
    Heat Exchanger MaterialStainless Steel (316), EPDM Gaskets
    Maximum Working Pressure Bar10
    Primary Pipework Connections2" > 2"
    Secondary Pipework Connections2" > 2"
    Manufacturers WarrantyAHRI Units 3 Years / Non AHRI Units 1 Year
  • Heat Load 300 KW *

    Secondary DHW Flow L/S1.43
    Secondary DHW Flow In Temperature 10
    Secondary DHW Flow Out Temperature °C60
    Secondary Pressure Drop KPA23
    Primary Hot Water Flow L/S2.39
    Primary Flow In Temperature oC80
    Primary Flow Out Temperature °C50
    Primary Pressure Drop KPA48
    Model ReferenceAEL-T5-MFG-20
    Dimensions mmHeight 700mm x Length 170mm x Width 260mm
    Weight Kg80
    Heat Exchanger MaterialStainless Steel (316), EPDM Gaskets
    Maximum Working Pressure Bar10
    Primary Pipework Connections2" > 2"
    Secondary Pipework Connections2" > 2"
    Manufacturers WarrantyAHRI Units 3 Years / Non AHRI Units 1 Year
  • Heat Load 350 KW *

    Secondary DHW Flow Rate L/S1.67
    Secondary DHW Flow In Temperature oC10
    Secondary DHW Flow Out Temperature °C60
    Secondary Pressure Drop KPA21
    Primary Flow Rate L/S2.79
    Primary OC80
    Primary Water Flow Out Temperature °C50
    Primary Pressure Drop KPA46
    Model ReferenceAEL-T5-MFG-24
    Dimensions mmHeight 700mm x Length 170mm x Width 260mm
    Weight Kg80
    Heat Exchanger MaterialStainless Steel (316), EPDM Gaskets
    Maximum Working Pressure Bar10
    Primary Pipework2" > 2"
    Secondary Pipework Connections2" > 2"
    Manufacturers WarrantyAHRI Units 3 Years / Non AHRI Units 1 Year
  • Heat Load 400 KW *

    Secondary DHW Flow L/S1.91
    Secondary DHW Flow In Temperature oC10
    Secondary DHW Flow Out Temperature °C60
    Secondary Pressure Drop KPA23
    Primary Hot Water Flow Rate L/S3.19
    Primary Flow In Temperature oC80
    Primary Flow Out Temperature °C50
    Primary Pressure Drop KPA51
    Heat ModelAEL-T5-MFG-26
    Dimensions mmHeight 700mm x Length 300mm x Width 260mm
    Weight Kg80
    Heat Exchanger MaterialStainless Steel (316), EPDM Gaskets
    Maximum Working Pressure Bar10
    Primary Pipework Connections2" > 2"
    Secondary Pipework Connections2" > 2"
    Manufacturers WarrantyAHRI Units 3 Years / Non AHRI Units 1 Year
  • Heat Load 450 KW *

    Secondary DHW Flow L/S2.15
    Secondary DHW Flow In Temperature oC 10
    Secondary DHW Flow Out Temperature °C60
    Secondary Pressure Drop KPA22
    Primary Hot Water Flow L/S3.59
    Primary Flow In Temperature oC80
    Primary Flow Out Temperature °C50
    Primary Pressure Drop KPA50
    Model ReferenceAEL-T5-MFG-30
    Dimensions mmHeight 700mm Length 300mm x Width 260mm
    Weight Kg90
    Heat Exchanger MaterialStainless Steel (316), EPDM Gaskets
    Maximum Working Pressure Bar10
    Primary Pipework Connections2" > 2"
    Secondary Pipework Connections2" > 2"
    Manufacturers WarrantyAHRI Units 3 Years / Non AHRI Units 1 Year
  • Heat Load 500 KW *

    Secondary DHW Flow L/S2.39
    Secondary DHW Flow In Temperature oC10
    Secondary DHW Flow Out Temperature °C60
    Secondary Pressure Drop KPA23
    Primary Hot Water Flow L/S3.99
    Primary Flow In Temperature oC80
    Primary Flow Out Temperature °C50
    Primary Pressure Drop KPA54
    Model ReferenceAEL-T5-MFG-32
    Dimensions mmHeight 700mm Length 300mm x Width 260mm
    Weight Kg90
    Heat Exchanger MaterialStainless Steel (316), EPDM Gaskets
    Maximum Working Pressure Bar10
    Primary Pipework Connections2" > 2"
    Secondary Pipework Connections2" > 2"
    Manufacturers WarrantyAHRI Units 3 Years / Non AHRI Units 1 Year
  • Heat Load 550 KW *

    Secondary DHW Flow Rate L/S2.63
    Secondary DHW Flow In Temperature oC10
    Secondary DHW Flow Out Temperature °C60
    Secondary Pressure Drop KPA22
    Primary Hot Water Flow Rate L/S4.39
    Primary Flow In Temperature oC80
    Primary Flow Out Temperature °C50
    Primary Pressure Drop KPA52
    Model ReferenceAEL-T5-MFG-36
    Dimensions mmHeight 700mm Length 300mm x Width 260mm
    Weight Kg90
    Heat Exchanger MaterialStainless Steel (316), EPDM Gaskets
    Maximum Working Pressure Bar10
    Primary Pipework Connections2" > 2"
    Secondary Pipework Connections2" > 2"
    Manufacturers WarrantyAHRI Units 3 Years / Non AHRI Units 1 Year
  • Heat Load 600 KW *

    Secondary DHW Flow Rate L/S2.87
    Secondary DHW Flow In Temperature oC10
    Secondary DHW Flow Out Temperature °C60
    Secondary Pressure Drop KPA22
    Primary Flow Rate L/S4.79
    Primary OC80
    Primary Water Flow Out Temperature °C50
    Primary Pressure Drop KPA51
    Model ReferenceAEL-T5-MFG-40
    Dimensions mmHeight 700mm Length 300mm x Width 260mm
    Weight Kg90
    Heat Exchanger MaterialStainless Steel (316), EPDM Gaskets
    Maximum Working Pressure Bar10
    Primary Pipework Connections2" > 2"
    Secondary Pipework Connections2" > 2"
    Manufacturers WarrantyAHRI Units 3 Years / Non AHRI Units 1 Year
  • Heat Load 650 KW *

    Secondary DHW Flow L/S3.11
    Secondary DHW Flow In Temperature oC10
    Secondary DHW Flow Out Temperature °C60
    Secondary Pressure Drop KPA23
    Primary Hot Water Flow Rate L/S5.19
    Primary Hot Water Flow In Temperature oC 80
    Primary Hot Water Flow Out Temperature °C50
    Primary Pressure Drop KPA55
    Model ReferenceAEL-T5-MFG-42
    Dimensions mmHeight 700mm Length 300mm x Width 260mm
    Weight Kg90
    Heat Exchanger MaterialStainless Steel (316), EPDM Gaskets
    Maximum Working Pressure Bar10
    Primary Pipework Connections2" > 2"
    Secondary Pipework Connections2" > 2"
    Manufacturers WarrantyAHRI Units 3 Years / Non AHRI Units 1 Year
  • Heat Load 700 KW *

    Secondary DHW Flow L/S3.35
    Secondary DHW Flow In Temperature oC10
    Secondary DHW Flow Out Temperature °C60
    Secondary Pressure Drop KPA22
    Primary Hot Water Flow L/S5.59
    Primary Hot Water Flow In Temperature oC80
    Primary Hot Water Flow Out Temperature °C50
    Primary Pressure Drop KPA54
    Model ReferenceAEL-T5-MFG-46
    Dimensions mmHeight 700mm Length 300mm x Width 260mm
    Weight Kg83
    Heat Exchanger MaterialStainless Steel (316), EPDM Gaskets
    Maximum Working Pressure Bar10
    Primary Pipework Connections2" > 2"
    Secondary Pipework Connections2" > 2"
    Manufacturers WarrantyAHRI Units 3 Years / Non AHRI Units 1 Year
  • Heat Load 750 KW *

    Secondary Flow Rate L/S3.59
    Secondary OC10
    Secondary DHW Water Flow Out Temperature °C60
    Secondary Pressure Drop KPA22
    Primary Hot Water Flow Rate L/S5.99
    Primary Hot Water Flow In Temperature °C80
    Primary Hot Water Flow Out Temperature °C50
    Primary Pressure Drop KPA53
    Heat ModelAEL-T5-MFG-50
    Dimensions mmHeight 700mm Length 300mm x Width 260mm
    Weight Kg100
    Heat Exchanger MaterialStainless Steel (316), EPDM Gaskets
    Maximum Working Pressure Bar10
    Primary Pipework Connections2" > 2"
    Secondary Pipework Connections2" > 2"
    Manufacturers WarrantyAHRI Units 3 Years / Non AHRI Units 1 Year
  • Heat Load 800 KW *

    Secondary DHW Flow L/S3.83
    Secondary DHW Flow In Temperature °C10
    Secondary DHW Flow Out Temperature °C60
    Secondary Pressure Drop KPA23
    Primary Flow Rate L/S6.38
    Primary OC80
    Primary Water Flow Out Temperature °C50
    Primary Pressure Drop KPA57
    Heat ModelAEL-T5-MFG-52
    Dimensions mmHeight 700mm Length 300mm x Width 260mm
    Weight Kg100
    Heat Exchanger MaterialStainless Steel (316), EPDM Gaskets
    Maximum Working Pressure Bar10
    Primary Pipework Connections2" > 2"
    Secondary Pipework Connections2" > 2"
    Manufacturers WarrantyAHRI Units 3 Years / Non AHRI Units 1 Year
  • Heat Load 850 KW *

    Secondary DHW Flow L/S4.06
    Secondary DHW Flow In Temperature °C10
    Secondary DHW Flow Out Temperature °C60
    Secondary Pressure Drop KPA24
    Primary Hot Water Flow Rate L/S6.78
    Primary Hot Water Flow In Temperature °C80
    Primary Hot Water Flow Out Temperature °C50
    Primary Pressure Drop KPA58
    Model ReferenceAEL-T5-BFG-68
    Dimensions mmHeight 700mm Length 300mm x Width 260mm
    Weight Kg100
    Heat Exchanger MaterialStainless Steel (316), EPDM Gaskets
    Maximum Working Pressure Bar10
    Primary Pipework Connections2" > 2"
    Secondary Pipework Connections2" > 2"
    Manufacturers WarrantyAHRI Units 3 Years / Non AHRI Units 1 Year
  • Heat Load 900 KW *

    Secondary DHW Flow Rate L/S4.30
    Secondary DHW Flow In Temperature °C10
    Secondary DHW Flow Out Temperature °C60
    Secondary Pressure Drop KPA24
    Primary Hot Water Flow Rate L/S7.18
    Primary Water Flow In Temperature °C80
    Primary Water Flow Out Temperature °C50
    Primary Pressure Drop KPA59
    Model Reference AEL-T5-BFG-72
    Dimensions mmHeight 700mm Length 300mm x Width 260mm
    Weight Kg100
    Heat Exchanger MaterialStainless Steel (316), EPDM Gaskets
    Maximum Working Pressure Bar10
    Primary Pipework Connections2" > 2"
    Secondary Pipework Connections2" > 2"
    Manufacturers WarrantyAHRI Units 3 Years / Non AHRI Units 1 Year
  • Heat Load 950 KW *

    Secondary DHW Flow L/S4.54
    Secondary DHW Flow In Temperature °C10
    Secondary DHW Flow Out Temperature °C60
    Secondary Pressure Drop KPA25
    Primary Hot Water Flow L/S7.58
    Primary Hot Water Flow In Temperature °C80
    Primary Hot Water Flow Out Temperature °C50
    Primary Pressure Drop KPA55
    Model ReferenceAEL-T6-BFM-38
    Dimensions mmHeight 880mm Length 490mm x Width 330mm
    Weight Kg150
    Heat Exchanger MaterialStainless Steel (316), EPDM Gaskets
    Maximum Working Pressure Bar10
    Primary Pipework Connections2" > 2"
    Secondary Pipework Connections2" > 2"
    Manufacturers WarrantyAHRI Units 3 Years / Non AHRI Units 1 Year
  • Heat Load 1000 KW *

    Secondary DHW Flow L/S4.78
    Secondary DHW Flow In Temperature °C10
    Secondary DHW Flow Out Temperature °C60
    Secondary Pressure Drop KPA25
    Primary Hot Water Flow L/S7.98
    Primary Water Flow In Temperature °C80
    Primary Water Flow Out Temperature °C50
    Primary Pressure Drop KPA56
    Model ReferenceAEL-T6-BFM-40
    Dimensions mmHeight 880mm Length 490mm x Width 330mm
    Weight Kg150
    Heat Exchanger MaterialStainless Steel (316), EPDM Gaskets
    Maximum Working Pressure Bar10
    Primary Pipework Connections2" > 2"
    Secondary Pipework Connections2" > 2"
    Manufacturers WarrantyAHRI Units 3 Years / Non AHRI Units 1 Year